Filtered categories:
A master PRV is allowed to be installed downstream of a fire pump when a second master PRV is installed to provide redundancy, so that failure of one PRV does not affect the operation of the fire protection system.
Was this helpful?
Yes, but with conditions. Residential hoods may be installed in employee kitchen areas, community centers in residential buildings, churches and similar areas that are not designed for the selling of food to the public. The cooking equipment shall be of residential grade, and a modification shall be approved by Mechanical Plan Check before installation.
Was this helpful?
In general, infiltration is not allowed within a Hillside Grading Area. However, consideration can be given for properties where slopes won't be impacted.
Was this helpful?
In general, infiltration is not allowed within a potentially liquefiable hazard zone. However, sites within a potentially liquefiable zone can be considered for infiltration if a soils report demonstrates that the site is not subject to liquefaction.
Was this helpful?
The Plumbing Code allows outdoor installations of water heaters. Check with the Zoning engineer for required minimum distance from the property line.
Was this helpful?
No.
Was this helpful?