Is a townhouse exempt from DA requirements?

No, a townhouse is not exempt. 

Published:
    Read FAQ
Is an elevator or lift required for a multi-story building?

An accessible route must be provided to connect each story and mezzanine in a multi-story building (see exceptions per 11B-206.2.3).

Published:
    Read FAQ
Is an elevator or lift required for a single-story building?

No, an elevator is not required for a single-story building.

Published:
    Read FAQ
Is turning space (5' circle) required inside the bathroom of an individual dwelling unit?

Yes, per 1134A4.

Published:
    Read FAQ
What DA upgrades need to be made when a commercial building is altered?

Alterations to an existing building must be provided with an accessible path of travel to the specific area of alteration. This includes the primary entrance to the building or facility, toilet or bathing facilities serving the area, drinking fountains, public telephones, and signs.

Published:
    Read FAQ
What is considered sufficient turning space?

Turning space shall be a circular space of 60” diameter, or a T-shaped space with a 60” length for arms width, and a base that is 36” wide. See 11B-304.3.2.

Published:
    Read FAQ
What is the maneuvering clearance at the door?

Door maneuvering clearances are determined based on Approach Direction -- from the front, hinge side, latch side, approach side, pull or push side -- whether the path is perpendicular or parallel to a doorway.

See Table 11B-404.2.4.1 for each case scenario.



Published:
    Read FAQ
What is the maximum allowable vertical drop on an accessible route?

¼ inch is the maximum. 

Published:
    Read FAQ
What is the maximum height for a DA counter?

34 inches is the maximum height.

Published:
    Read FAQ
What is the maximum height of kitchen counter tops inside the unit?

36 inches is the maximum height.